< Previous   Next >

2014 - Mazda6 - Body and Accessories

DTC U3003:16 [FORWARD SENSING CAMERA (FSC)]



Description

Forward sensing camera (FSC) low power supply voltage input

Detection condition

  • Forward sensing camera (FSC) power supply circuit voltage of 7.2 V or less is detected for 5 s or more with the ignition switched ON (engine off or on).

Fail-safe function

  • Inhibits the lane departure warning system (LDWS).

  • Inhibits the high beam control (HBC) system.

Possible cause

  • DTCs are stored in the PCM.

  • Battery malfunction

  • Generator malfunction

  • Forward sensing camera (FSC) connector or terminal malfunction

  • Forward sensing camera (FSC) power supply circuit malfunction

    • Short to ground in wiring harness between C/U IG1 15 A fuse and forward sensing camera (FSC) terminal I

    • C/U IG1 15 A fuse malfunction

    • Open circuit in wiring harness between IG1 relay and forward sensing camera (FSC) terminal I

  • Forward sensing camera (FSC) malfunction


Diagnostic Procedure

Step

Inspection

Action

1

VERIFY PCM DTCs

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [SKYACTIV-G 2.5].)

No

Go to the next step.

2

INSPECT BATTERY

Yes

Go to the next step.

No

Recharge or replace the battery, then go to Step 6.

(See BATTERY RECHARGING [SKYACTIV-G 2.5].)

(See BATTERY REMOVAL/INSTALLATION [SKYACTIV-G 2.5].)

3

INSPECT GENERATOR

Yes

Go to the next step.

No

Replace the generator, then go to Step 6.

(See GENERATOR REMOVAL/INSTALLATION [i-ELOOP].)

(See GENERATOR REMOVAL/INSTALLATION [SKYACTIV-G 2.5 (WITHOUT i-ELOOP)].)

4

INSPECT FORWARD SENSING CAMERA (FSC) CONNECTOR
  • Switch the ignition off.

  • Disconnect the negative battery cable.

    (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.5].)

  • Disconnect the forward sensing camera (FSC) connector.

  • Inspect the connector engagement and connection condition and inspect the terminals for damage, deformation, corrosion, or disconnection.

  • Is the connector normal?

Yes

Go to the next step.

No

Repair or replace the connector, then go to Step 6.

5

VERIFY FORWARD SENSING CAMERA (FSC) POWER SUPPLY VOLTAGE

Yes

Go to the next step.

No

Inspect the C/U IG1 15 A fuse.

  • If the fuse is burnt out:

    • Refer to the wiring diagram and verify whether or not there is a common connector between C/U IG1 15 A fuse and forward sensing camera (FSC) terminal I.

      • If there is a common connector:
      • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for a short to ground.

      • Repair or replace the malfunctioning part.

        If there is no common connector:
      • Repair or replace the wiring harness which has a short to ground.

      • Replace the fuse.

  • If the fuse is damaged:

    • Replace the fuse.

  • If the fuse is normal:

    • Refer to the wiring diagram and verify whether or not there is a common connector between IG1 relay and forward sensing camera (FSC) terminal I.

      • If there is a common connector:
      • Determine the malfunctioning part by inspecting the common connector and the terminal for corrosion, damage, or pin disconnection, and the common wiring harness for an open circuit.

      • Repair or replace the malfunctioning part.

        If there is no common connector:
      • Repair or replace the wiring harness which has an open circuit.

Go to the next step.

6

VERIFY THAT REPAIRS HAVE BEEN COMPLETED

Yes

Repeat the inspection from Step 1.

Go to the next step.

No

Go to the next step.

7

VERIFY IF OTHER DTCs DISPLAYED
  • Are any other DTCs displayed?

Yes

Repair or replace the malfunctioning part according to the applicable DTC troubleshooting.

(See DTC TABLE [FORWARD SENSING CAMERA (FSC)].)

No

DTC troubleshooting completed.




< Previous   Next >